Table 11
Industry standard for corrosion weight loss measurement guideline [130–132]
Corrosion rate (mg/(cm2 a)) | Corrosion depth (mm/a) | Recommendation |
>1000 | 2 | Completely destroyed within days |
100–999 | 0.1–1.99 | Not recommended for service greater than a month |
50–90 | 0.1–0.19 | Not recommended for service greater than 1 year |
10–49 | 0.02–0.19 | Caution recommended, based on the specific application |
0.3–9.9 | − | Recommended for long-term service |
<0.2 | − | Recommended for long-term service; no corrosion, other than as a result of surface cleaning, was evidenced |