Table 3
The advantages and disadvantages of analytical instruments for radionuclides
Category | Analytical Instrument | Advantages | Disadvantages |
Radiometric Techniques | Alpha Spectrometry | High sensitivity | Only detects alpha particles |
High resolution | High sample preparation requirements | ||
Simple operation | Limited alpha particle energy range | ||
Low cost | Sensitive to environmental conditions | ||
Liquid Scintillation Counter (LSC) | High sensitivity | High sample preparation requirements | |
High efficiency | Sensitive to chemical quenching | ||
Versatility | Sensitive to chemical quenching | ||
Automation | High cost of scintillation solution | ||
Gamma Spectrometry | High sensitivity and selection | Limited to gamma emitters | |
Non-destructive | Interferences | ||
Relatively fast | Expensive | ||
Low-Energy Inorganic Mass Spectrometry | Inductively Coupled Plasma Mass Spectrometry (ICP-MS) | High sensitivity | Interferences |
Multi-elemental capability | Limited information about chemical speciation | ||
Isotopic analysis | Expensive | ||
Thermal Ionization Mass Spectrometry (TIMS) | High precision and accuracy | Limited elemental coverage | |
High sensitivity | Time-consuming analysis | ||
Isotopic analysis | Limited sample size | ||
Quantitative analysis | Expensive | ||
Long-term stability | |||
Resonance Ionization Mass Spectrometry (RIMS) | High sensitivity and selection | Limited elemental coverage | |
Isobaric interference-free | Time-consuming analysis | ||
High spatial resolution | Limited availability | ||
Quantitative analysis | |||
Glow Discharge Mass Spectrometry (GDMS) | High sensitivity | Expensive | |
High elemental coverage | Limited sample size | ||
Quantitative analysis | Time-consuming analysis | ||
Depth profiling capability | Limited spatial resolution | ||
Secondary Ion Mass Spectrometry (SIMS) | High spatial resolution | Expensive | |
High sensitivity | Limited sample size | ||
Isotopic analysis | Time-consuming analysis | ||
Depth profiling capability | |||
Multi-elemental capability | |||
3H-3He Ingrowth Mass Spectrometry | High sensitivity | Only for tritium | |
Isotopic specificity | Time-consuming analysis | ||
Quantitative analysis | Limited information about chemical speciation | ||
Positive-Ion Mass Spectrometry | High sensitivity | Limited elemental coverage | |
Multi-elemental capability | Limited information about chemical speciation | ||
Isotopic analysis | Quantitative analysis challenges | ||
Fast | Interferences | ||
Accelerator Mass Spectrometry | Accelerator Mass Spectrometry (AMS) | Ultra-high sensitivity | Complex instrumentation |
Isotopic specificity | Time-consuming analysis | ||
Quantitative analysis | High capital cost | ||
Wide range of applications | Limited availability |