Table 1

HC-ARF-based gas sensors employing different sensing technologies

Methods Gas Laser wavelength (μm) Integration time (s) LoD (ppb) NEA (cm−1) NNEA (W cm−1 Hz−1/2) Ref.
TDLAS C2H2 10.500 80 10 4.0 × 10−7 [42]
CO2 2.000 10 34300 [128]
CO 2.300 100 220 [129]
PTS NO 5.260 144 11 4.29 × 10−7 [130]
CH4 1.651 450 24.2 7.43 × 10−9 [131]
C2H2 1.532 450 11.6 1.35 × 10−8  
NH3 1.532 450 46.1 9.87 × 10−9  
CH4 1.654 200 0.015 5.6 × 10-12 [132]
C2H2 1.532 113 0.0027  
O2 0.761 70 560  
H2O 1.390 1000 222 3.57 × 10−9 [133]
CO2 2.000 1000 1.5 2.33 × 10−9  
CO 4.600 1000 0.6  
CO 4.602 600 35 [134]
CO2 2.004 280 120  
C2H4 3.346 280 310  
C2H6 3.348 280 49  
C2H2 1.530 320 1 1 × 10-9 [135]
PAS C2H2 1.533 100 8 2.81 × 10−8 [102]
FERS CH4 0.532 60 1200 [136]
C2H4 60 1600  
C2H2 60 2700  
C2H6 60 2900  
H2 60 13800  
CO 60 16700  
H2 0.532 30 11200 [137]
C2H2 30 3100  
CO2 30 9400  
C2H4 30 4800  
CH4 30 1500  
CO 30 17900  
13C16O2 0.532 900 135 [138]
12C16O2 900 510  
12C16O18O 900 221  
CH4 900 98  
13CO2 0.532 300 70 [139]
12CO2 300 640  
CLaDS C2H6 3.336 25 0.0155 3.5 × 10−10 [113]
HPSDS NO 5.260 80 800 [114]
CH4 1.654 1285 1220 [140]
LITES CH4 1.651 100 220 8.23 × 10−8 2.04 × 10−11 [141]
N2O 4.570 50 40 8.6  ×  10–7 [142]
CO2 2.006 100 20000 1.7  ×  10–6  
CO 2.330 100 3850 1.15 × 10−7 [116]
C2H2 1.530 100 1670 [143]