Table 2
Summary of photocatalytic U(VI) based on CMP materials
Photocatalysts | Photocatalytic conditions | Sacrifice | Light sources | Removal rate (%) | Ref |
Ph(PhXOD)3-CMP | C0 = 10 ppm m/V = 0.25 g·L−1 |
No | 300 W Xe lamp | ~93% in 3 h | [104] |
DA-CMP-3 | C0 = 50 ppm m/V = 0.5 g·L−1, pH = 5.0 |
20 vol% MeOH |
blue LED lamp | ~97% in 240 min | [105] |
TT-TPP | C0 = 200 ppm m/V = 1 g·L−1 pH = 2.8 |
AA | 40 W LED lamp | ~97.5% in 10 h | [107] |
pTTT-Ben | C0 = 50 ppm m/V = 1g·L−1 pH = 5.0 |
AA | 300 W Xe lamp | ~78% in 4 h | [108] |
ECUT-AQ | C0 = 50 ppm m/V = 0.25 g·L−1 pH = 5.0 |
AA | 300 W Xe lamp | ~86% in 120 min | [109] |
PyCMP-3 | C0 = 100 ppm m/V = 0.4 g·L−1 pH = 6.0 |
No | 300 W Xe lamp | ~99.5% in 5 h | [110] |
PTrSO-2 | C0 = 50 ppm m/V = 0.5 g·L−1 pH = 4.0 |
10 vol% MeOH |
300 W Xe lamp | ~99.5% in 120 min | [111] |
PBSOTH-2 | C0 = 100 ppm m/V = 0.5 g·L−1 pH = 4.0 |
10 vol% MeOH |
300 W Xe lamp | ~99.2% in 120 min | [72] |
PQ-TPM | C0 = 50 ppm m/V = 5 g·L−1 pH = 4.0 |
5 vol% MeOH |
350 W Xe lamp | ~99.4% in 20 min | [112] |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.