Table 3
Summary of photocatalytic U(VI) based on COF materials
Photocatalysts | Photocatalytic conditions | Bonding mode | Removal rate (%) | Ref |
TpBpy | C0 = 0.12 mM, m/V = 0.5 g·L−1, pH = 7.0, 500 W Xe lamp | vinylene-linked | ~93% in 20 min | [113] |
TTT−DTDA | C0 = 25 ppm, m/V = 1.0 g·L−1, pH = 5.0, 300 W Xe lamp | fused-bithiophene linkers | ~98.2% in 10 h | [114] |
Tp-Tapb | C0 = 0.12 mM, m/V = 1 g·L−1, 350 W Xe lamp | β-keto-enamine | ~92% in 15 min | [19] |
TFPPy-DP | C0 = 0.12 mM, m/V = 0.5 g·L−1, 350 W Xe lamp | amide linkages | ~90% in 20 min | [34] |
LB-COF | C0 = 8 ppm, m/V = 8.0 g·L−1, pH = 5.5, 300 W Xe lamp | imine- and vinyl-linkages | 320 mg·g−1 in 150 min | [115] |
TP-TMT | C0 = 50 ppm, m/V = 1.0 g·L−1, pH = 4.0, 300 W Xe lamp | vinylene-linked | 83% in 240 min | [116] |
Tp-DBD | C0 = 35 ppm, m/V = 0.1 g·L−1, pH = 6.0, 300 W Xe lamp | benzoxazole ring | 10.31 mg·g−1 in 2 h | [117] |
PI-3-AR | C0 = 83 ppm, m/V = 0.17 g·L−1 pH = 4.0, 300 W Xe lamp |
amine-linked | 278 mg·g−1 in 4 h | [118] |
SnS2COF | C0 = 50 ppm, m/V = 0.5 g·L−1, pH = 5.0, 350 W Xe lamp 2 mM HCO3 |
β-ketoenamine, II-type heterojunction | ~95% in 180 min | [36] |
BiOBr@TpPa-1 | C0 = 30 ppm, pH = 6.0, m/V = 0.33 g·L−1, 350 W Xe lamp | β-ketoenamine | ~91% in 540 min | [51] |
TiOCs@COF-TZ | C0 = 8 ppm, m/V = 1 g·L−1, pH = 8.5, 420 nm |
coordinated metal clusters | ~99.86% in 25 min | [120] |
TT-Por COF-Ni | C0 = 50 ppm, m/V = 0.1 g·L−1 pH = 9.0, 350 W Xe lamp |
imine bond | ~97.1% in 360 min | [121] |
Cu-TMT | C0 = 50 ppm, m/V = 0.25 g·L−1 pH = 5.0, 350 W Xe lamp, hole scavenger 0.1 mL |
sp2-c linked | ~98.1% in 360 min | [122] |
NDA-TN-AO | C0 = 10 ppm, m/V = 1 g·L−1 pH = 5.0, 350 W Xe lamp |
vinyl linked | 4.62 mg·g−1 | [124] |
4-Pd-AO | C0 = 10 ppm, m/V = 1 g·L−1 pH = 5.0, 350 W Xe lamp |
β-ketoenamine | 7.36 mg·g−1 in 3 h | [125] |
COF 2-Ru-AO | C0 = 10 ppm, m = 10 mg pH = 5.5, 350 W Xe lamp |
β-ketoenamine | 6.07 mg·g−1 in 27 h | [126] |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.